LumberCon planks have been tested by independent labs for fire, freeze/thaw and slip resistance. Each summary below explains what was tested and what the results mean. Download the full reports to share with your architect, engineer, building department or insurer.

Fire: Noncombustible and Class A

ASTM E136 tests whether a material burns or adds heat to a fire. LumberCon met all of the test’s passing criteria, so it is classified as noncombustible.

ASTM E84 measures how fast flame spreads across a surface. LumberCon scored a Flame Spread Index of 0, which is Class A.

View the fire test reports

Freeze / Thaw

Three LumberCon planks were kept fully surrounded by a 10% salt solution through 25 freeze-thaw cycles, following NYSDOT Method 502-3P (modified for full-size planks). Every sample lost less than 0.01% of its weight. The NYSDOT limit is 1.00%. The lab noted some surface pitting, mostly on the underside.

Download the report (PDF)

Slip Resistance

Tested by an independent lab in August 2026 under ANSI A326.3 and ASTM E303. LumberCon’s wood-grain surface measured a wet dynamic coefficient of friction (DCOF) of 0.65 and a dry DCOF of 0.67. That meets the ANSI A326.3 criterion for exterior, wet surfaces, which is a minimum of 0.55. The British Pendulum test gave wet values of 55 to 58 and dry values of 63 to 77. ASTM E303 has no pass/fail threshold.

Download the summary report (PDF)

Other Documents

Results apply to the samples tested. Check with your local building department for project requirements.